🔎 Overview
The Herschel Krystal Low-Profile Surface Mounting Kit is a ceiling mounting accessory designed for installing Herschel Krystal 600W and 1000W infrared heaters on suitable solid or non-recessed ceilings. Available in Black and White, the kit provides a neat, low-profile installation with a surrounding frame that complements the heater's compact ceramic-glass design.
Unlike the Krystal Ceiling Recess Kit, this surface mounting kit does not require a large opening to be cut into the ceiling or an available ceiling void. It allows the heater to remain below the ceiling surface while providing a more integrated appearance than the standard swivel brackets supplied with the Krystal heater.
Both the Black and White mounting kits fit the corresponding 600W and 1000W Krystal panels. The heater and its required Herschel iQ thermostat are purchased separately. Installation must follow the Krystal mounting instructions and be completed with suitable structural fixings and professional electrical connections.
📏 Size & Fit Information
The Herschel Krystal Low-Profile Surface Mounting Kit is designed to fit both the 600W and 1000W Krystal infrared heaters.
Both heating outputs use the same 570 × 270 mm panel dimensions, so there is no need to select a different mounting-kit size based on wattage.
Choosing the correct finish
- Black – KRYSTAL-SMK-LB: Designed for the Black Krystal 600W and 1000W infrared heaters.
- White – KRYSTAL-SMK-LW: Designed for the White Krystal 600W and 1000W infrared heaters.
Choose the finish that best matches the installed heater and surrounding ceiling.
Ceiling fitment
The kit mounts the heater below the finished ceiling surface rather than recessing it into a ceiling cavity.
The Krystal mounting diagram shows approximately 100 mm from the ceiling surface to the front face of the heater for this arrangement.
This measurement should be considered when checking the available overhead space and the installed height above the floor.
The separate external dimensions of the surrounding frame are not published, so the installer should confirm its full footprint before drilling or positioning the ceiling fixings.
Installation height
The surface-mount installation instructions specify a minimum installed heater height of 2.1 metres above the floor.
The Krystal heater guidance also recommends ceiling heights of at least 2.4 metres for ceiling-mounted installations.
Both requirements should be considered when planning the final position.
📘 Additional Information & Resources
The Herschel Krystal Low-Profile Surface Mounting Kit is an optional accessory for the Krystal infrared heating range.
It is designed for customers who want a neat ceiling-mounted appearance without installing the heater inside a ceiling recess.
Alternative mounting options
The Krystal heater is supplied with swivel mounting brackets for suitable wall or ceiling installation.
For a completely different ceiling finish, the optional Krystal Ceiling Recess Kit allows the heater to be installed within a suitably constructed plasterboard ceiling opening.
The Low-Profile Surface Mounting Kit and Ceiling Recess Kit are separate accessories designed for different installation methods.
Warranty and maintenance
The surface mounting kit carries a one-year accessory warranty.
The Krystal infrared heater has its own separate five-year warranty.
Periodically inspect the mounting arrangement during scheduled heater maintenance.
Before inspection or cleaning, isolate the heater's electrical supply and allow it to cool completely.
🧱 Surface Mounting vs Ceiling Recess Mounting
Herschel Krystal heaters offer different ceiling installation options depending on the building's construction and desired appearance.
Low-Profile Surface Mounting Kit
The surface mounting kit fixes the heater below the finished ceiling.
It is suitable where a neat surrounding frame is preferred but a recessed installation is impractical.
Typical applications include:
- Suitable solid ceilings.
- Ceilings without an accessible cavity.
- Rooms where a recessed opening cannot be accommodated.
- Installations where a finished ceiling surface should be retained.
The heater remains visible below the ceiling, with a surrounding frame providing a tidy appearance.
Ceiling Recess Kit
The optional ceiling recess kit is designed for suitable plasterboard ceilings with an accessible void.
It allows the Krystal heater to be installed into a prepared ceiling opening for a more flush, integrated appearance.
A suitable ceiling cavity, cut-out dimensions and the required heat clearances must be available.
Standard Swivel Brackets
Swivel brackets are included with the Krystal heater itself.
They provide a separate mounting option for suitable wall or ceiling installations.
Customers who are satisfied with the standard swivel-bracket installation do not need to purchase either optional ceiling kit.
🌬️ Installation Clearances & Safety Requirements
The Herschel Krystal is a high-temperature infrared heater, so correct positioning and safe mounting are essential.
The Low-Profile Surface Mounting Kit must be installed according to the requirements for the heater and the selected ceiling structure.
Important installation requirements
- Installed height: The surface-mount instructions specify at least 2.1 metres between the floor and the installed heater.
- Ceiling height: A minimum ceiling height of 2.4 metres is recommended for Krystal ceiling installations.
- Ceiling-to-front distance: The mounting arrangement is shown at approximately 100 mm from the ceiling surface to the heater's front face.
- Structural support: The supporting ceiling and fixings must be suitable for the combined heater and mounting assembly.
- Heat-sensitive materials: Maintain the required separation from combustible or temperature-sensitive objects.
- Heating surface: Keep the front of the heater unobstructed so infrared warmth can radiate into the room.
- Electrical cable: Route the heater cable safely, away from high-temperature surfaces.
- Occupant access: Install the heater beyond the normal reach of people using the room.
- Installer access: Allow for safe servicing and future removal of the heater if required.
High-temperature operation
The Herschel Krystal heater operates at surface temperatures of approximately 280–350°C.
The kit must not be modified or used to position the heater inside an unsuitable enclosure.
Do not cover the heater or obstruct its ceramic-glass heating surface.
The complete installation must comply with the current mounting instructions and relevant Australian electrical and building requirements.
🎯 Ideal Applications
The Low-Profile Surface Mounting Kit is suitable for indoor spaces where a compact ceiling-mounted heater is preferred.
Living rooms
The surface mounting arrangement allows Krystal heating to be incorporated into a suitable ceiling without using valuable wall space.
Kitchens and dining areas
A ceiling-mounted Krystal can provide radiant heating while leaving wall areas available for cabinetry, furniture and other fittings.
Bedrooms
The compact mounting arrangement is useful where unobstructed walls are preferred.
Hallways
Krystal heaters can be positioned in suitable hallway ceilings, with the mounting surround providing a neat finish.
Home offices
Overhead infrared heating can keep wall and floor space available for desks, storage and other equipment.
Commercial interiors
The mounting kit may be used with appropriately installed Krystal heaters in offices, reception areas and other suitable indoor commercial spaces.
The selected location must meet the heater's mounting-height, clearance and electrical requirements.